(Event Number)
67. Add System Features
SYSTEM FEATURES
68. Delete All Relay Features added by Function 67.
; 6 8 ; 0 0 0 :
Relay Features (12-24. Reserved)
1. Remote Input switch closed and Function 65 Remote Input
enabled. Because the Remote Input is enabled by factory default,
the Relay will energize when the Remote Input switch is closed.
7. Scheduled Lock Event. Relay energizes for 2 seconds when lock
is locked by a Schedule.
2. Remote Input switch closed and Function 64 Remote Input
disabled. If the Remote Input is disabled with Function 64, the Re-
lay will NOT energize when the Remote Input Switch is closed.
8. Scheduled Unlock Event. Relay energizes for 2 seconds when
lock is unlocked by a schedule
3. Failed attempted entry. Relay energizes for 2 seconds when an
attempted User Code entry via the keypad fails.
9. Lock Out. Relay energizes for 2 seconds when a Lock Out occurs
(i.e. number of attempts is exceeded, see Function 60).
4. Disabled User or Group. Relay energizes for 2 seconds when a
disabled User or disabled Group member enters a User Code.
10. Ambush. Relay energizes for 2 seconds when Ambush is tripped.
See Function 66, page 25.
5. Follow Access Granted. When a valid User Code is entered into
the keypad and the lock unlocks, the Relay energizes for 2 seconds.
Compare with Event 31.
11. First Key Press. Relay energizes for 2 seconds at the first key
press of any sequence.
6. Group 1 User Code. Relay energizes for 2 seconds when a sched-
uled Group 1 User Code is entered. See Function 90, page 29.
31. Follow Access Granted--No Time Limit.** When a valid User
Code is entered into the keypad and the lock unlocks, the Relay
energizes for the same amount of time as the programmed Pass
Time. (The Pass Time is the length of time the lock stays
unlocked after a valid User Code is entered. See functions
52-54). Use this feature for remote monitoring or other activation.
Use Function 67 to program one or more lock events and the Relay will energize when the programmed event(s) listed below oc-
curs. For example, program ; 6 7 ; 3 : and when an attempted entry fails (such as a User who enters an
incorrect or un-programmed User Code), the Relay will energize for 2 seconds. Note: For more information about the Remote In-
put, see page 11 (Wiring, Remote Input) and page 25 (Function 65).
4
System Options
25. Disable Sounder
26. 5 sec. Delayed Entry *
27. 15 sec. Delayed Entry *
28. 45 sec. Delayed Entry *
Remote Input Functions
29. Toggle Passage Mode. Remote Input toggles Passage
Mode.
30. Forced Unlock Follows Remote Input.** When Remote
Input activated, the Relay will energize regardless of its cur-
rent state.
32. Remote Input Disables Unit.** Regardless of the current
state, that state will remain unchanged (and keypad will be
disabled) for the duration of Remote Input switch closure.
* Features 26, 27 & 28 will delay User Codes 12 and higher only (except 297, 298 and 299).
** Features 30, 31 & 32 should be used with External DC Power unless feature is used for short a duration and infrequently (sustained
closure of remote input or Relay will drain batteries, and scheduled events will not occur during sustained closure of remote input).
Sustained closure of remote input may affect proper audit trail operation.
NOTE: Enter ; 6 7 ; 0 0 0 : to delete all Relay Features added by Function 67 (identical to Function 68).
PC Communication Functions
33. Remote Input Puts Unit in PC Communication Mode
Enter ; 6 8 ; 0 0 0 : to delete all Relay Features added by Function 67.
4
Programming Functions (cont'd)
Ambush Function
1. Connect relay to a device able to properly monitor dry contacts for an Ambush condition.
2. Program the Relay for Ambush Tripped using Program Function 67(10) above.
3. Set the Ambush Code using Program Function 66.
4. When the Ambush Code is entered followed by a valid User Code, the relay will close for 2 seconds.
Notes: The Ambush Code defaults to 99. An error will sound if you try to program a new User Code starting with the Ambush Code.