24
;62 ; [ _ _ _ _ ] ; [ _ _ _ _ _ _ ] :
(User Number) (User Code)
60. Number of Attempts Before Lockout
61. Set the Attempts Lockout Time
LOCKOUT
; 6 4 :
64. Disable Remote Input
Remote Input
; 6 5 :
65. Enable Remote Input
66. Reserved
• Number of attempts before lockout must be 1-9 attempts.
• The number of attempts is reduced by half every time the keypad is locked out without a successful code entry (default is
6 attempts).
• The attempt count is reset each time a valid code is entered.
• Lockout Time must be 1-60 seconds.
How long the keypad is locked-out after a series of unsuccessful attempts (default is 18 seconds).
• Wire a Normally Open Contact to Wires (White & White). Momentarily close switch to unlock door to allow person to pass through door.
• Enter the functions below to Disable/Enable the Remote Input.
NOTE: The Remote Input is enabled as part of the default program.
REMOTE INPUT
; 6 0 ; [ _ ] :
(Number of Attempts)
; 6 1 ; [ _ _ ] :
(Lockout Time)
Programming Functions (cont'd)
59. Reserved
4
2
62. Add/Delete/Change User Codes 2-2000
(for Primary Side code entry)
• User Number must be between 2 and 2000. User Codes entered are enabled for use with the Primary side keypad only.
• To delete a code, leave the User Code blank and wait for the rapid beeping to stop, then press and hold : for three seconds
to exit Programming Mode. If more programming is desired, re-enter Programming Mode.
• User Code must be 3-6 digits.
• Each User Code can be thought of as a person. As long as each person possesses their own unique User Code, you can con-
trol access to the lock by adding or deleting User Codes. See "Terminology Used in this Manual" on page 6 for more information.
3
4
;63 ; [ _ _ _ _ ] ; [ _ _ _ _ _ _ ] :
(User Number) (User Code)
63. Add/Delete/Change User Codes 2-2000
(for Secondary Side code entry)
• Same as Function 62, except User Codes entered are enabled for use with the Secondary side keypad only.
3