21
Function Card #6
IMPORTANT NOTE:
Function Cards 3 through 7 are not recognized by DL-Windows. Therefore, DL-Windows will not send the data for
Function Cards 3-7 to the AL-DTM, nor will the AL-DTM be able to send this Function Card data to the PL3000
lock. Accordingly, Function Cards are designed to be used for limited-use installations where DL-Windows will not
be used. When User Numbers are printed in the Audit log, Function Cards 3-7 will appear as User Numbers
2003-2007.
Initiates AL-IR1 Printing With Time, Date, Version Number and Audit Trail Log
Function Card #6 is used to initiate the printing of the Audit Log by the AL-IR1 Wireless Printer. The time,
date and version number will also be printed. The AL-IR1 is optically linked to the PL3000 lock via infrared light,
and therefore must be held approximately 1" to 4" above the infrared LED (as shown in image below). Be sure
fresh batteries are installed in the AL-IR1 Wireless Printer before proceeding. Note: Time and date must be
set using DL-Windows or the AL-DTM.
Print the Audit Log as follows:
1. Turn on the printer.
2. Place AL-IR1 approximately 1" to 4" above the infrared LED (as shown in image).
3. Present Function Card #6 to the lock. The lock will beep twice (and flash a green LED).
4. After a 2-second delay, the PL3000 lock will send the infrared signals to the printer.
5. If more than 20 log entries exist in the lock, after the 20th entry a line will print: "More?". The lock will
beep twice every second (with a green LED) for 15 seconds. (If there are less than 20 log entries, the
lock will end the printing sequence and return to normal operation).
To continue printing, re-present a card to print the next 20 Logs (during which the beeping and flashing
will stop). Step 5 will be repeated if more logs exist.
If a card is not presented, the lock will end the printing sequence within 15 seconds (signified by a red
LED and two beeps), after which the lock will return to normal operation.
Note: Turn off the printer when not in use.
Function Card # 6
AC
Adapter
(Optional)
Paper Compartment
Optical
Receiver
Thermal
Print Head
On/Off
Print
Contrast
Paper
Advance
Power ON
Indicator
Light
Infrared
LED
Infrared
Receiver
AL-IR1 to PL3000 (side and front views)