23
To Disarm a Burglary Control Panel
90. Relay Activation
(Open Time Window)
; 9 0 ; [ _ ] ; [ _ _ _ _ ] :
• Also program Relay Function 6 using Function 67 (; 6 7 ; 6 :).
• For day enter: 1 for Sunday, 2 for Monday, 3 for Tuesday, 4 for Wednesday, 5 for
Thursday, 6 for Friday and 7 for Saturday, 8 for Monday to Friday, 9 for Saturday and
Sunday, 0 for all days of week.
• Enter time of day in 24 hour format.
Enter the Open and Close Window Functions below to set up a Window where if any Group
1 User Code is entered within the programmed window the relay will be activated for 2
seconds. For use with a Control Panel that has a key switch disarm option. See Disarming a
Burglar Alarm on page 5.
Scheduled Relay Activation (Group 1 Activated)
; 9 1 ; [ _ ] ; [ _ _ _ _ ] :91. Relay Activation
(Close Time Window)
SCHEDULES GROUP 1 ACTIVATED
3
Control
Panel
Relay
Output
Switch
Input
Alarm Panel with Switched Input for Disarming
Control
Panel
Relay
Output
Switch
Input
External
Relay
Lug
Alarm Panel with Switched Input for Toggled Arm/Disarm
Notes:
1. Group 1 Disarms a Burglary Control
Panel will always disarm an alarm system.
Arming should be performed by other
means (such as Alarm Panel Keypad/
Schedule).
2. Use a qualified electrical/alarm specialist
to review your current alarm system and
add additional components as needed
(such as a relay, wire, resistors, connectors
and/or diodes) and change the operation of
your alarm system (by programming).